Performance Comparison of Biotest Sterile Gamma-Irradiated Contact Slides DE-Gamma with Non-Irradiated D/E-Agar by Juergen Horn, Ph.D. September 2002
 
This paper compares gamma-irradiation sterilized, modified DE Agar with standard non-irradiated D/E-Agar for recovery of organisms and capacity for neutralizing disinfecting agents. The neutralizing capacity was tested using 4 microorganisms (gram positive coccos, gram positive rod) with a wide range of disinfecting agents neutralized by D/E-Agar including aldehydes, phenol, quaternary agents, chlorine compounds, and hydrogen peroxide. The radiation-sterilized medium neutralized each disinfectant as well as the non-irradiated medium and fertility was equal or better on radiation sterilized DE Agar compared with standard D/E-Agar.
 
Comparative Air Sampling in Isolators Using RCS-Highflow with TCI-gamma Against M-Air Tester With Antiperoxide Cassettes and the MD8 Air Scan With Gelatine Filters by Juergen Horn, Ph.D. December 2002
 
This poster session compares the hydrogen peroxide neutralization capacity of several viable airborne monitoring methods that are currently used in isolator systems.
 